Dry Screw Vacuum pump SDV + Vacuum Booster

 Screw Type Dry Vacuum Pumping System [SDV Series]
Model MKBM 890

SDV 200

MKBM 1680

SDV 320

MKBM 3370

SDV 430

MKBM 8200

SDV 800

Capacity M3/hr 740 1400 2800 6600
Ultimate Pressure Torr 5 x 10-2 5 x 10-2 5 x 10-2 5 x 10-2
Booster HP 5 5 7.5 15
Vacuum Pump HP 5 10 15 20
Starting Pressure Torr 40 20 20 20
Inlet Connection mm/Inch 100/4” 150/6” 150/6” 300/12”
Discharge Connection mm/Inch 40/1-1/2” 50/2” 50/2” 65/2-1/2”
Weight Kgs. 850 1200 1500 2200

Dry Screw Vacuum pump KDP + Vacuum Booster

 Screw Type Dry Vacuum Pumping System [KDP Series]
Model MKBM 890

SDV 150

MKBM 1680

KDP 330

MKBM 3370

SDV 400

MKBM 8200

SDV 800

Capacity M3/hr 740 1400 2800 6600
Ultimate Pressure Torr 5 x 10-2 5 x 10-2 5 x 10-2 5 x 10-2
Booster HP 5 5 7.5 15
Vacuum Pump HP 7.5 12.5 20 30
Starting Pressure Torr 40 20 20 20
Inlet Connection mm/Inch 100/4” 150/6” 150/6” 300/12”
Discharge Connection mm/Inch 40/1-1/2” 50/2” 50/2” 65/2-1/2”
Weight Kgs. 1000 1400 1800 2500

Accessories for Screw Type Dry Vacuum Pumping System

Vacuum System Electro Pneumatic Butterfly Isolation

Make : Marck/aira [Cair]
Type : Electro Pneumatic Butterfly Valve
MOC : SS 304/SS 316/Carbon Steel
Lining : PTFE [Optional]
Operation : Electro pneumatic
Working Pressure : 5-7 Kg/Cm2
Solenoid Valve Coil : Flame Proof
Supply Voltage : 230 V Ac. Single Phase, 50 Hz

Vacuum Switch with Digital Display

Make : Taie
Range : 760 to 0.1 torr
Sensor : Vacuum Transducer
Location : At Booster Suction
Enclosure : Flame Proof
Wetted Parts : SS 304

Temperature Switch with Digital Display

Make : Taie
Range : 0 to 100 Deg. C
Sensor : RTD [PT100] Sensor
Location : At Booster Discharge
Enclosure : Flame Proof
Wetted Parts : SS 304

Rinsing Vessel

A 10 Ltrs Tank is provided for periodic flushing of the Pump. Recommended Solvent is flushed for a short period on a cyclic basis. Timer with solenoid valve provided for regulating the flushing procedure.

Solenoid Valve : Flame Proof
Electrical Rating : 230 V Ac, 1 Ph, 50 Hz
Rinsing Vessal : 10 Ltrs.
MOC : SS 304

N2 Purging System

The N2 Purging / Flushing Unit is provided for flushing of the Pump. The flushed for a short period at the time of on & off of the Screw Type Dry Vacuum Pump. Timer with solenoid valve provided for regulating the flushing procedure.

Solenoid Valve : Flame Proof
Electrical Rating : 230 V Ac, 1 Ph, 50 Hz
Pressure Regulator : for N2
Rota meter / Flow Meter : 0 to 50 LPM

Electrical Control Panel – Flame Proof / Non Flame Proof

Contactors and relays for the pumps, Vacuum pumping unit ON/OFF Switch, Mains Indicating and pump operating Indication Lamps with overload indications & Variable Frequency Drive.

Optional : Relay logic / PLC / HMI